OpenPlant Modeler Help

Reducers Placement

Placement of Reducers usually consists of the following common steps:
  1. Set the size and spec in the Standard Preferences dialog.
  2. Select an option from the Reducers gallery.
  3. The Spec Record Selection dialog displays listing the reducing sizes. Select the record with the desired reducing size and click OK.
  4. Define the Placement Point (Main Port, Run Port etc.) and component settings in the Place Component dialog.
  5. Use the mouse to pick placement and direction points for Concentric reducers, and placement, direction and rotation picks for Eccentric reducers.
    Note: If connecting to an existing component, then only placement and rotation picks are required.